Signal Pre-Processing

This section describes how slow and fast filters are applied to current, cell voltage, and temperature for different BMS functions

Calibration Parameters

\[ N_{\text{slo}} = 10, \quad N_{\text{fast}} = 5 \]

Slow Inputs (SOC Function, 200 ms)

The State of Charge (SOC) function requires slow filtering.

  • Current filter:
\[ I_{\text{filt-slo}}(k) = \frac{1}{N_{\text{slo}}} \sum_{i=0}^{N_{\text{slo}}-1} I(k-i) \]
  • Cell Voltage filter:
\[ V_{\text{cell, filt-slo}}(k) = \frac{1}{N_{\text{slo}}} \sum_{i=0}^{N_{\text{slo}}-1} V_{\text{cell}}(k-i) \]
  • Temperature filter:
\[ T_{\text{filt-slo}}(k) = \frac{1}{N_{\text{slo}}} \sum_{i=0}^{N_{\text{slo}}-1} T(k-i) \]

Fast Inputs (SOP Function, 100 ms)

The State of Power (SOP) function requires fast filtering.

  • Current filter:
\[ I_{\text{filt-fast}}(k) = \frac{1}{N_{\text{fast}}} \sum_{i=0}^{N_{\text{fast}}-1} I(k-i) \]
  • Cell Voltage filter:
\[ V_{\text{cell, filt-fast}}(k) = \frac{1}{N_{\text{fast}}} \sum_{i=0}^{N_{\text{fast}}-1} V_{\text{cell}}(k-i) \]
  • Temperature filter:
\[ T_{\text{filt-fast}}(k) = \frac{1}{N_{\text{fast}}} \sum_{i=0}^{N_{\text{fast}}-1} T(k-i) \]

Synchronization Rule

Important

Whenever a function uses current and voltage together,
it must consistently use either slow-filtered or fast-filtered signals,
but never mix them.
This ensures synchronization of current & voltage measurements.